What is the standard for fire doors? According to the Chinese national standard GB12955-2008 fire door heating test results, if the insulation fire door test specimen meets the following conditions (a) to (v), it can be regarded as meeting the requirements of type A (heat-resisting) fire doors. Only when the following conditions (a) to (iv) are met, it can be regarded as complying with the B (non-heat-resisting) fire door regulations. 1. Insulation fire doors do not produce changes that are considered to be harmful to fire, such as deformation, destruction, exfoliation, and peeling. 2. Insulation fire doors do not produce flames that reach the non-heated surface of the test specimen and cracks or holes that are harmful to the fire. 3. Insulation fire door heating test In any part of the test specimen perimeter (door leaf), the reflex or deflection does not exceed half of the thickness of the door leaf. Fourth, heat insulation fire door heating test non-heating surface of the test did not produce a combustion flame. Fifth, heat insulation fire door heating test in the highest non-heating surface temperature does not exceed 960 °C. In a word, within a certain period of time, including thermal insulation and fireproof doors, door sills and hardware fittings, they can meet the complete fire resistance, flame resistance, and thermal insulation integrity of the door group, that is, relatively stable in the fire field. , do not allow the penetration of fire smoke and heat insulation source conduction and other basic properties, in order to control the fire in the fire zone dash, do not delay the burning or ignite another fire, the door with this basic performance can be called "insulated fire door All materials must be tested by the designated laboratories of the Ministry of Economic Affairs. What is the classification of fire doors? Fire safety facilities that prevent fires or underground fires from spreading and control winds are usually designed as steel insulated fire doors or wooden fire doors. Class A Class A insulation fire door, fire resistance limit 1.5 hours Class B insulation fire door, fire resistance 1.0 hours Class C insulation fire doors, fire resistance limit 0.5 hours SPR rubber Vertical Slurry Pump Naipu SPR rubber Vertical Slurry Pumps are vertical, centrifugal slurry pumps submerged in sump to work.They are designed for delivering abrasive,large particle and high density slurries.These pumps have no need of any shaft seal and sealing water. They can also be operated normally for insufficient suction duties.Wet parts of type NP-SP pump are made of abrasion-resistant metal. All parts of type NP-SP(R) pump immersed in liquid are lined with rubber outer liner.They are suited to transport non-edge angle abrasive slurry.
Magnetite mixing
NP-SPR Construction Drawing
Main Part Number At The Drawing
Materials of Construction
IMPELLERS
CASING
COLUMN
DISCHARGE
SEALS
Standard
High Chrome Alloy Rubber
High Chrome Alloy Rubber
Mild Steel
Mild Steel
Natural Rubber
Options
Butyl
Neoprene
Neoprene
Neoprene
Nordel
Selection Chart
SP SUMP PUMP PERFORMANCE PARAMETERS
Type
Allowable Mating Max. Power(Kw)
Range Of Performance
Impeller
Capacity/Q
Head/m
Speed/rpm
Max Efficiency/%
No. of Vanes
Impeller Diameter/mm
m³/hr
L/S
40PV-NP-SP
15
19.44-43.2
5.4-12
4.5-28.5
1000-2200
40
5
188
65QV-NP-SP
30
23.4-111
6.5-30.8
5-29.5
700-1500
50
5
280
100RV-NP-SP
75
54-289
15-80.3
5-35
500-1200
56
5
370
150SV-NP-SP
110
108-479.16
30-133.1
8.5-40
500-1000
52
5
450
200SV-NP-SP
110
189-891
152.5-247.5
6.5-37
400-850
64
5
520
250TV-NP-SP
200
261-1089
72.5-302.5
7.5-33.5
400-750
60
5
575
300TV-NP-SP
200
288-1267
80-352
6.5-33
350-700
50
5
610
Spr Rubber Vertical Slurry Pump,40Pv Rubber Slurry Pump,65Qv Rubber Vertial Pump,100Rv Rubber Slurry Pump Shijiazhuang Naipu Pump Co., Ltd. , https://www.naipu-pump.com
Typical Applications---
Sump drainage washdown
Floor drainage
Mill sumps
Carbon transfer
Monitoring
2.Column
3.Strainer
4.Back Liner
6.Pump Casing
7.Lower Pipe
Mild Steel Rubber Lined
Mild Steel Rubber Lined
Rubber
EPDM
Hypalon
Polyurethane
316 SS
W 151
Butyl
EPDM
Hypalon
Nitrile
316 SS
W 151
Butyl
Nitrile
316 SS
Butyl
Nitrile
316 SS
Neoprene
Viton
Hypalon
Butyl
EPDM
What is the standard for fire doors?
1.Discharge Pipe
5.Impeller